{"id":3119,"date":"2025-06-02T15:57:34","date_gmt":"2025-06-02T13:57:34","guid":{"rendered":"https:\/\/pqs.com.pa\/?page_id=3119"},"modified":"2025-06-02T16:08:35","modified_gmt":"2025-06-02T14:08:35","slug":"analisis-de-calidad-de-energia-de-eventos-impredecibles","status":"publish","type":"page","link":"https:\/\/pqs.com.pa\/en\/analisis-de-calidad-de-energia-de-eventos-impredecibles\/","title":{"rendered":"An\u00e1lisis de Calidad de Energ\u00eda de Eventos Impredecibles"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"3119\" class=\"elementor elementor-3119\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8856fb2 e-flex e-con-boxed e-con e-parent\" data-id=\"8856fb2\" data-element_type=\"container\" data-settings=\"{&quot;ekit_has_onepagescroll_dot&quot;:&quot;yes&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\r\n\t\t<div class=\"elementor-element elementor-element-b9d2424 elementor-widget elementor-widget-text-editor\" data-id=\"b9d2424\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\"><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-1\"><p>Los Transitorios y las variaciones cortas no pueden ser medidas de manera tradicional ya que ocurren solo moment\u00e1neamente durante un largo periodo de tiempo. La grabaci\u00f3n de dichos eventos se basa usualmente en limites configurados de acuerdo al Regulador \/ Empresa de Servicios p\u00fablicos y son com\u00fanmente llamados C\u00f3digos de Red. Sin embargo, algunos fen\u00f3menos no est\u00e1n cubiertos por el c\u00f3digo de Red, o los limites exigidos por el c\u00f3digo de red son irrelevantes para instalaciones espec\u00edficas. por ejemplo, un motor grande causa una gran ca\u00edda de tensi\u00f3n en todas las plantas cercanas durante su arranque. La queja es remitida a la compa\u00f1\u00eda de servicios p\u00fablicos, Que mide la tensi\u00f3n en la subestaci\u00f3n a unos cuantos km de distancia. La respuesta ser\u00e1 que el evento no fue detectado o grabado por ninguno de sus dispositivos de medici\u00f3n.<\/p><p>Otros ejemplos y casos reales est\u00e1n incluidos en el siguiente cap\u00edtulo<\/p><\/div><div class=\"fusion-clearfix\">\u00a0<\/div><\/div><\/div><\/div><\/div><div id=\"Tap-Changer\" class=\"fusion-container-anchor\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\"><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\">Error en el Cambiador de Tap de un Transformador<\/h2><\/div><div class=\"fusion-text fusion-text-2\"><p>Una auditor\u00eda de Calidad de energ\u00eda fue ejecutaba por la compa\u00f1\u00eda de servicios el\u00e9ctricos de Israel (IEC) a petici\u00f3n d euno de sus clientes en Alta tensi\u00f3n.\u00a0<a href=\"https:\/\/www.elspec-ltd.com\/metering-protection\/g4500-power-qaulity-analyzer-portable\/\">El G4500\u00a0<\/a>Analizador de Calidad de Energ\u00eda, fue instalado en el primario del transformador de distribuci\u00f3n. Al final de la auditor\u00eda, No se detect\u00f3 ning\u00fan evento tradicional por el\u00a0<a href=\"https:\/\/www.elspec-ltd.com\/medicion-y-proteccion\/?lang=es\">dispositivo. La figura 1 (abajo) muestra los valores RMS en 1\/2 ciclo durante 15 horas. La tabla permite observar que el nivel de tensi\u00f3n esta 3.1% por encima del valor nominal 22kV y que se present\u00f3 una ca\u00edda de tensi\u00f3n de 4% con respecto al valor nominal. Los valores medidos se encuentran dentro del est\u00e1ndar de la norma EN510160.<\/a><\/p><p>La figura 2 (abajo) es un acercamiento a una de las ca\u00eddas de tensi\u00f3n, la tensi\u00f3n cay\u00f3 en pasos de 200V cada 40 segundos y se elev\u00f3 con los mismos pasos pero en un periodo de tiempo m\u00e1s corto. La duraci\u00f3n total del evento fue de 8 minutos. Esto indica que hay una falla en el controlador del tap transformador. Esta informaci\u00f3n desencaden\u00f3 una actividad de mantenimiento y el tap del transformador fue reparado.<\/p><\/div><div class=\"fusion-clearfix\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-3120 aligncenter\" src=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/1y2.jpg\" alt=\"\" width=\"1033\" height=\"471\" srcset=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/1y2.jpg 1033w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/1y2-300x137.jpg 300w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/1y2-1024x467.jpg 1024w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/1y2-768x350.jpg 768w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/1y2-600x274.jpg 600w\" sizes=\"(max-width: 1033px) 100vw, 1033px\" \/><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"awb-gallery-wrapper awb-gallery-wrapper-1 button-span-no\"><div class=\"fusion-gallery fusion-gallery-container fusion-grid-2 fusion-columns-total-2 fusion-gallery-layout-masonry fusion-gallery-1 fusion-masonry-has-vertical\"><div class=\"fusion-grid-column fusion-gallery-column fusion-gallery-column-2 hover-type-none fusion-grid-sizer\">\u00a0<\/div><div class=\"fusion-grid-column fusion-gallery-column fusion-gallery-column-2 hover-type-none fusion-element-grid\"><div class=\"fusion-gallery-image\"><div class=\"fusion-masonry-element-container lazyloaded\" data-bg=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2018\/05\/Voltage-drop-distribution-line.png\">\u00a0\u00a0<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div id=\"Maquina-Soldadura\" class=\"fusion-container-anchor\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\"><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2>\u00a0Industria Automovil\u00edstica, Aplicaci\u00f3n para equipos de Soldadura en Industria de Autom\u00f3viles<\/h2><\/div><div class=\"fusion-text fusion-text-5\"><p>La figura 3 (abajo) muestra una vista general de las fluctuaciones de tensi\u00f3n en una planta de autom\u00f3viles. Durante estos 20 minutos la tensi\u00f3n fluct\u00faa r\u00e1pidamente a -15% de la tensi\u00f3n nominal. Programando l\u00edmites de 10% como dicta la norma, dar\u00e1 como resultado una saturaci\u00f3n de eventos que llenar\u00e1 la memoria.<\/p><p>Las mediciones continuas a una resoluci\u00f3n de 1\/2 ciclo durante un largo periodo de tiempo permite una investigaci\u00f3n de la intensidad de las ca\u00eddas causadas por las operaciones de soldadura ejecutadas al mismo tiempo. Una ca\u00edda por debajo de cierto nivel puede causar un da\u00f1o grave en la calidad de la producci\u00f3n, lo cual involucra la actividad de retirar el chassis defectuoso para reparaci\u00f3n y regresarlo posteriormente a la l\u00ednea de producci\u00f3n y mantenimiento.<\/p><p>La Figura 4 muestra un acercamiento durante 8 segundos en la fluctuaci\u00f3n de tensi\u00f3n.<\/p><p><img decoding=\"async\" class=\"size-full wp-image-3121 aligncenter\" src=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/4y56.jpg\" alt=\"\" width=\"1011\" height=\"471\" srcset=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/4y56.jpg 1011w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/4y56-300x140.jpg 300w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/4y56-768x358.jpg 768w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/4y56-600x280.jpg 600w\" sizes=\"(max-width: 1011px) 100vw, 1011px\" \/><\/p><\/div><div class=\"fusion-clearfix\">\u00a0<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-8\"><p>Cuando se usa un sistema de compensaci\u00f3n en tiempo real (EQ), se logra alcanzar una amplia mejora en los niveles de flicker e intensidad de las ca\u00eddas de tensi\u00f3n<\/p><\/div><div class=\"fusion-clearfix\">\u00a0<\/div><\/div><\/div><\/div><\/div><\/div><div id=\"Flicker-problema\" class=\"fusion-container-anchor\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-5 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\"><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-11 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-4 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\">Solucionando problemas de flicker a un cliente<\/h2><\/div><div class=\"fusion-text fusion-text-9\"><p>En el siguiente ejemplo el cliente se quej\u00f3 por un parpadeo en su iluminaci\u00f3n. Se decidi\u00f3 instalar un analizador de calidad de energ\u00eda para realizar una investigaci\u00f3n de 1 semana.<\/p><p>La figura 5 (abajo) brinda una visi\u00f3n general de la tensi\u00f3n RMS con una resoluci\u00f3n de 1 ciclo y los valores PST por m\u00e1s de 8 d\u00edas. Inesperadamente los valores PST est\u00e1n dentro del rango permitido (Abajo 1).<\/p><\/div><div class=\"fusion-image-element in-legacy-container\">\u00a0<img decoding=\"async\" src=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2018\/05\/Flicker-values.png\" alt=\"Solucionando problemas de flicker a un cliente\" \/><\/div><div class=\"fusion-text fusion-text-10\"><p>Figura 5: Vista General Tensi\u00f3n y PST durante 8 d\u00edas<\/p><\/div><div class=\"fusion-clearfix\">\u00a0<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-12 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-11\"><p>La figura 6 (abajo) muestra el THDV y los valores del 7mo arm\u00f3nico a una resoluci\u00f3n de 1 ciclo. El gr\u00e1fico permite ver claramente que el patr\u00f3n del THDV y el 7mo arm\u00f3nico es el mismo. LAs figuras 7 y 8 son acercamientos a un momento particular en el que el 7mo arm\u00f3nico est\u00e1 activo. Muestra que promediar los valores de arm\u00f3nicos en un intervalo de 10 minutos, como lo exige el est\u00e1ndar, filtrar\u00e1 este fen\u00f3meno. La figura 9 muestra claramente la deformaci\u00f3n de la forma de onda causada por el 7mo arm\u00f3nico.<\/p><p>La raz\u00f3n para el elevado 7<sup>mo<\/sup>\u00a0arm\u00f3nico fue en parte por un fen\u00f3meno de resonancia en la red cercano al 7<sup>mo<\/sup>\u00a0arm\u00f3nico que ocurri\u00f3 cuando algunos bancos de condensadores fueron conectados. La raz\u00f3n por la cual no fue completamente 7<sup>mo<\/sup>\u00a0arm\u00f3nico, fue debido a que hay una peque\u00f1a escala de arm\u00f3nicos generada por una planta de potencia hidr\u00e1ulica en la planta. El generador en esta planta era asincr\u00f3nico, y a medida que el rotor se retrasa 50 Hz se genera un deslizamiento, un 7<sup>mo<\/sup>\u00a0\u00a0arm\u00f3nico del rotor se transforma en un am\u00f3nico interno cercano al 7<sup>mo<\/sup>\u00a0arm\u00f3nico.\u00a0 \u00a0 \u00a0<\/p><\/div><\/div><\/div><\/div><\/div><\/div><div id=\"Pre-Falla\" class=\"fusion-container-anchor\"><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-6 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\"><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-14 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-5 fusion-sep-none fusion-title-text fusion-title-size-two\">\u00a0<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-18 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-15\">\u00a0<\/div><\/div><\/div><\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aebca71 elementor-arrows-position-inside elementor-pagination-position-outside elementor-widget elementor-widget-image-carousel\" data-id=\"aebca71\" data-element_type=\"widget\" data-settings=\"{&quot;navigation&quot;:&quot;both&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;pause_on_hover&quot;:&quot;yes&quot;,&quot;pause_on_interaction&quot;:&quot;yes&quot;,&quot;autoplay_speed&quot;:5000,&quot;infinite&quot;:&quot;yes&quot;,&quot;speed&quot;:500,&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"image-carousel.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-image-carousel-wrapper swiper\" role=\"region\" aria-roledescription=\"carousel\" aria-label=\"Carrusel de im\u00e1genes\" dir=\"ltr\">\n\t\t\t<div class=\"elementor-image-carousel swiper-wrapper\" aria-live=\"off\">\n\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"1 of 4\" data-no-translation-aria-label=\"\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/RMS-THD-Harmonics-320x202-1-150x150.png\" alt=\"RMS-THD-Harmonics-320x202\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"2 of 4\" data-no-translation-aria-label=\"\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/Waveform-harmoni-voltage-current-320x202-1-150x150.png\" alt=\"Waveform-harmoni-voltage-current-320x202\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"3 of 4\" data-no-translation-aria-label=\"\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/zoom-in-waveform-harmonics-320x202-1-150x150.png\" alt=\"zoom-in-waveform-harmonics-320x202\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"4 of 4\" data-no-translation-aria-label=\"\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/waveform-with-7th-harmonic-320x202-1-150x150.png\" alt=\"waveform-with-7th-harmonic-320x202\" \/><\/figure><\/div>\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-prev\" role=\"button\" tabindex=\"0\">\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-left\"><\/i>\t\t\t\t\t<\/div>\n\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-next\" role=\"button\" tabindex=\"0\">\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-right\"><\/i>\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"swiper-pagination\"><\/div>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75cce10 elementor-widget elementor-widget-text-editor\" data-id=\"75cce10\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"fusion-title title fusion-title-5 fusion-sep-none fusion-title-text fusion-title-size-two\"><h2 class=\"fusion-title-heading title-heading-left\">An\u00e1lisis previo a la falla del Tap del transformador<\/h2><p>\u00a0<\/p><\/div><div class=\"fusion-text fusion-text-12\"><p>La compa\u00f1\u00eda el\u00e9ctrica de Israel report\u00f3 cambios en los Taps de los transformadores. Cuando est\u00f3 ocurri\u00f3, las mediciones mostraron que durante la operaci\u00f3n de cambio de Tap en alta tensi\u00f3n, la tensi\u00f3n cambi\u00f3 aproximadamente en 0.5%. Este cambio de nivel no puede ser grabado ya que est\u00e1 muy lejos de los ajustes de los limites programados para las grabaciones. Lo que significa es que el evento no se grab\u00f3. Tambi\u00e9n cabe anotar que en t\u00e9rminos de calidad de energ\u00eda, este evento no fue relevante.<\/p><p>En la figura 10 (abajo), hay tres pasos que presentan tres niveles de tensi\u00f3n. En el primer paso, hay un alto nivel de THDV por encima del 3.2% (El THDV se midi\u00f3 a una resoluci\u00f3n de 1 ciclo).<\/p><p>El acercamiento al primer paso de la figura 11 (abajo) muestra que la se\u00f1al de tensi\u00f3n est\u00e1 distorsionada. Esto indica un problema potencial en el tap del transformador. Esta informaci\u00f3n conllev\u00f3 a una actividad de mantenimiento en la que se pudo reparar el tap del transformador.<\/p><p><img decoding=\"async\" class=\"size-full wp-image-3129 alignleft\" src=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/10y11.jpg\" alt=\"\" width=\"1000\" height=\"470\" srcset=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/10y11.jpg 1000w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/10y11-300x141.jpg 300w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/10y11-768x361.jpg 768w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/06\/10y11-600x282.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0dd7215 elementor-widget elementor-widget-text-editor\" data-id=\"0dd7215\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Cuando se usa un sistema de compensaci\u00f3n en tiempo real (EQ), se logra alcanzar una amplia mejora en los niveles de flicker e intensidad de las ca\u00eddas de tensi\u00f3n<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Los Transitorios y las variaciones cortas no pueden ser medidas de manera tradicional ya que ocurren solo moment\u00e1neamente durante un largo periodo de tiempo. La grabaci\u00f3n de dichos eventos se basa usualmente en limites configurados de acuerdo al Regulador \/ Empresa de Servicios p\u00fablicos y son com\u00fanmente llamados C\u00f3digos de Red. Sin embargo, algunos fen\u00f3menos&#8230;<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3119","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/pages\/3119","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/comments?post=3119"}],"version-history":[{"count":6,"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/pages\/3119\/revisions"}],"predecessor-version":[{"id":3132,"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/pages\/3119\/revisions\/3132"}],"wp:attachment":[{"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/media?parent=3119"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}