{"id":2807,"date":"2025-05-26T20:19:13","date_gmt":"2025-05-26T18:19:13","guid":{"rendered":"https:\/\/pqs.com.pa\/?page_id=2807"},"modified":"2025-05-26T20:46:11","modified_gmt":"2025-05-26T18:46:11","slug":"g5dfr","status":"publish","type":"page","link":"https:\/\/pqs.com.pa\/en\/g5dfr\/","title":{"rendered":"G5DFR"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"2807\" class=\"elementor elementor-2807\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7216b3f e-flex e-con-boxed e-con e-parent\" data-id=\"7216b3f\" data-element_type=\"container\" data-settings=\"{&quot;ekit_has_onepagescroll_dot&quot;:&quot;yes&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-faa253a elementor-widget elementor-widget-heading\" data-id=\"faa253a\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Multi-Functional Digital Fault Recorder<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edb11d elementor-widget elementor-widget-heading\" data-id=\"8edb11d\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.elspec-ltd.com\/contact-us\/\" style=\"font-family: &quot;Source Sans Pro&quot;, Arial, Helvetica, sans-serif;font-size: 28.5px;font-weight: 400;text-align: center\">Get a Quote&gt;&gt;<\/a><span style=\"font-family: &quot;Source Sans Pro&quot;, Arial, Helvetica, sans-serif;font-size: 28.5px;font-weight: 400;text-align: center\">&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;<\/span><a href=\"https:\/\/www.elspec-ltd.com\/metering-protection\/g5-multi-functional-digital-fault-recorder\/#Live-Demo\" style=\"font-family: &quot;Source Sans Pro&quot;, Arial, Helvetica, sans-serif;font-size: 28.5px;font-weight: 400;text-align: center\">Live Demo&gt;&gt;<\/a><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0964dc0 e-flex e-con-boxed e-con e-parent\" data-id=\"0964dc0\" data-element_type=\"container\" data-settings=\"{&quot;ekit_has_onepagescroll_dot&quot;:&quot;yes&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-61b0204 elementor-widget elementor-widget-image\" data-id=\"61b0204\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/05\/elspec-website-DFR-e1728557564873-400x400-1.jpg\" class=\"attachment-large size-large wp-image-2810\" alt=\"\" srcset=\"https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/05\/elspec-website-DFR-e1728557564873-400x400-1.jpg 400w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/05\/elspec-website-DFR-e1728557564873-400x400-1-300x300.jpg 300w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/05\/elspec-website-DFR-e1728557564873-400x400-1-150x150.jpg 150w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/05\/elspec-website-DFR-e1728557564873-400x400-1-90x90.jpg 90w, https:\/\/pqs.com.pa\/wp-content\/uploads\/2025\/05\/elspec-website-DFR-e1728557564873-400x400-1-100x100.jpg 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\r\n\t\t<div class=\"elementor-element elementor-element-80ab7b5 elementor-widget elementor-widget-text-editor\" data-id=\"80ab7b5\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: #747474; font-family: 'Source Sans Pro', Arial, Helvetica, sans-serif; font-size: 19px; text-align: center;\">The BlackBox G5DFR is a fully featured digital fault recorder equipped with PQZIP technology. The G5DFR\u00a0 is a distributed multi-functional data acquisition device that continuously records all waveform signals at sampling rate of 1,024 samples per cycle.<\/span><\/p><div class=\"heading heading-with-icon icon-left\"><div class=\"image\" aria-hidden=\"true\"><img decoding=\"async\" class=\"ls-is-cached lazyloaded\" src=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2025\/01\/PQZIP-icon-200x200.png\" alt=\"\" width=\"45\" height=\"45\" data-orig-src=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2025\/01\/PQZIP-icon-200x200.png\" \/><\/div><h3 class=\"content-box-heading\">PQZIP inside<\/h3><\/div><div class=\"fusion-clearfix\">\u00a0<\/div><div class=\"content-container\"><div data-canvas-width=\"269.2032\">Continuous waveform recording<br \/>Trigger free setup<br \/>5,000 power parameters @ 1\/2 cycle resolution<br \/>Easy deployment<\/div><div data-canvas-width=\"269.2032\">\u00a0<\/div><\/div><div class=\"heading heading-with-icon icon-left\"><div class=\"image\" aria-hidden=\"true\"><img decoding=\"async\" class=\"ls-is-cached lazyloaded\" src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/03\/Certificate.png\" alt=\"\" width=\"45\" height=\"45\" data-orig-src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/03\/Certificate.png\" \/><\/div><h3 class=\"content-box-heading\">Class A<\/h3><\/div><div class=\"fusion-clearfix\">\u00a0<\/div><div class=\"content-container\"><div data-canvas-width=\"269.2032\">Far surpassing the highest standards set by the industry, the BLACKBOX device series complies with standards for: aggregations, time clock uncertainty, flagging, and transient influence quantities.<\/div><\/div><div data-canvas-width=\"269.2032\"><div class=\"heading heading-with-icon icon-left\"><div class=\"image\" aria-hidden=\"true\"><img loading=\"lazy\" decoding=\"async\" class=\"ls-is-cached lazyloaded\" src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/03\/Accuracy.png\" alt=\"\" width=\"45\" height=\"45\" data-orig-src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/03\/Accuracy.png\" \/><\/div><h3 class=\"content-box-heading\">Superior Accuracy<\/h3><\/div><div class=\"fusion-clearfix\">\u00a0<\/div><div class=\"content-container\"><div data-canvas-width=\"161.10753792000003\">The G5DFR is equipped with 24 bit ADC\u00a0 to yield, a superior accuracy far surpassing IEC 61000-4-30 Class A requirements, thereby capturing the finest details<\/div><div data-canvas-width=\"207.4688\">&amp; deviations in PQ parameters.<\/div><\/div><\/div><div data-canvas-width=\"207.4688\"><div class=\"heading heading-with-icon icon-left\"><div class=\"image\" aria-hidden=\"true\"><img loading=\"lazy\" decoding=\"async\" class=\"ls-is-cached lazyloaded\" src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/03\/TimeSync.png\" alt=\"\" width=\"45\" height=\"45\" data-orig-src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/03\/TimeSync.png\" \/><\/div><h3 class=\"content-box-heading\">Synchronized Monitoring<\/h3><\/div><div class=\"fusion-clearfix\">\u00a0<\/div><div class=\"content-container\"><div data-canvas-width=\"258.1376\">The BLACKBox DFR\u2019s synchronization algorithm is based on several sources with an automatic hierarchy for the preferred source availability (accuracy based hierarchy). This\u00a0unique time synchronization algorithm assures that logged data from multiple units is synchronized &amp; displayed on the same time scale with typical 1 \u03bcs resolution.<\/div><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4d11cae e-flex e-con-boxed e-con e-parent\" data-id=\"4d11cae\" data-element_type=\"container\" data-settings=\"{&quot;ekit_has_onepagescroll_dot&quot;:&quot;yes&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d22881 elementor-widget elementor-widget-text-editor\" data-id=\"4d22881\" data-element_type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\">\n<div class=\"fusion-builder-row fusion-row\">\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-two\">\n<h3>Multi-functional Recorder<\/h3>\n<\/div>\n<div class=\"fusion-sep-clear\">&nbsp;&nbsp;<\/div>\n<div class=\"fusion-text fusion-text-6\">\n<ul>\n<li>Digital Fault Recorder (DFR)<\/li>\n<li>Phasor Measurement Unit (PMU)<\/li>\n<li>Power Quality Monitoring (PQM)<\/li>\n<li>Sequence of Event Recording (SER)<\/li>\n<li>Dynamic System Monitoring (DSM)<\/li>\n<li>Impedance based Fault Location (IbFL)<\/li>\n<li>Energy Billing Measurement (EBM)<\/li>\n<li>Impedance&nbsp;Distance to&nbsp;Fault Location (IDFL)<\/li>\n<\/ul>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-two\">\n<h3>Unique Features<\/h3>\n<\/div>\n<div class=\"fusion-sep-clear\">&nbsp;&nbsp;<\/div>\n<div class=\"fusion-text fusion-text-7\">\n<ul>\n<li>24-Bit Continuous acquisition at 1,024 sample per cycle[50\/60Hz]<\/li>\n<li>Modular Design<\/li>\n<li>Centralized and decentralized architecture<\/li>\n<li>Supreme synchronization<\/li>\n<li>Complies with IEC 61850 MMS, GOOSE messaging and sample value<\/li>\n<li>Comprehensive web interface<\/li>\n<li>7\u201d touch LCD<\/li>\n<li>Scalable architecture<\/li>\n<\/ul>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-5 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\">\n<div class=\"fusion-builder-row fusion-row\">\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last fusion-animated\" data-animationtype=\"fadeInDown\" data-animationduration=\"0.8\" data-animationoffset=\"top-into-view\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div><p><img decoding=\"async\" class=\"ls-is-cached lazyloaded\" src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/08\/continuous-waveform-recording.png\" data-orig-src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/08\/continuous-waveform-recording.png\"><\/p>\n<div id=\"waveform-text\">\n<h3>Continuous Waveform Recordings<\/h3>\n<p>the G5DFR is a multi-functional recorder able to record and store all electrical waveform at any given time, for more than a year, with no gaps in the data. RMS, harmonics and any other values from waveform in post-processing are calculated, including the tabulation of more than 10,000 parameters.<\/p>\n<p><a href=\"https:\/\/elspec-ltd.com\/advanced-use-of-continues-waveform-power-quality-analyzer\/\">Read more &gt;&gt;<\/a><\/p><\/div>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-6 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling fusion-equal-height-columns\">\n<div class=\"fusion-builder-row fusion-row\">\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-column-content-centered\">\n<div class=\"fusion-column-content\">\n<div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-text fusion-title-size-two\">\n<h3>Supreme Trends Resolution<\/h3>\n<\/div>\n<div class=\"fusion-sep-clear\">&nbsp;<\/div>\n<div class=\"fusion-separator fusion-clearfix\">\n<div class=\"fusion-separator-border sep-single sep-solid\">&nbsp;<\/div>\n<\/div>\n<div class=\"fusion-sep-clear\">&nbsp;<\/div>\n<div class=\"fusion-text fusion-text-8\">\n<p>The G5DFR measures and records 5,000 power parameters continuously at a resolution of \u00bd cycles, 10\/12 cycles, 150\/180 cycles, 10 min and 2 hours of which, any given resolution is calculated for display and reporting purposes. Hence, there is no need to select which parameters to log, and more importantly, which parameters to ignore.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-11 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-column-content-centered\">\n<div class=\"fusion-column-content\">\n<div class=\"fusion-image-element in-legacy-container\"><span class=\"fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive wp-image-1081 ls-is-cached lazyloaded\" title=\"Elspec-website-ProductsPage-2.1_03\" src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Elspec-website-ProductsPage-2.1_03-e1460978000584.png\" alt=\"5 K Parameters icon\" width=\"361\" height=\"350\" data-orig-src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Elspec-website-ProductsPage-2.1_03-e1460978000584.png\"><\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-7 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling fusion-equal-height-columns\">\n<div class=\"fusion-builder-row fusion-row\">\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-12 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-column-content-centered\">\n<div class=\"fusion-column-content\">\n<div class=\"fusion-image-element in-legacy-container\"><span class=\"fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive wp-image-3126 lazyautosizes ls-is-cached lazyloaded\" title=\"Power-quality-Harmonics\" src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics.png\" sizes=\"576px\" srcset=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics-200x107.png 200w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics-400x214.png 400w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics-600x321.png 600w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics.png 683w\" alt=\"power quality harmonics chart\" width=\"683\" height=\"365\" data-orig-src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics.png\" data-srcset=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics-200x107.png 200w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics-400x214.png 400w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics-600x321.png 600w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-Harmonics.png 683w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 800px) 100vw, 600px\"><\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-13 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-column-content-centered\">\n<div class=\"fusion-column-content\">\n<div class=\"fusion-title title fusion-title-4 fusion-sep-none fusion-title-text fusion-title-size-two\">\n<h3>Harmonics &amp; Inter-Harmonics Analysis<\/h3>\n<\/div>\n<div class=\"fusion-sep-clear\">&nbsp;&nbsp;<\/div>\n<div class=\"fusion-text fusion-text-9\">\n<p>The G5DFR power quality analyzer boosts&nbsp;two FFT engines for harmonics analysis: Cycle by Cycle: performs FFT at 1 cycle resolution for extended bandwidth. This engine provides 512 harmonics order at 50Hz resolution. 10\/12 Cycles: performs FFT 10\/12 cycles resolution for extended resolution and sub-grouping calculation. This engine provides the magnitude and angle of 512 spectrum components at 5Hz resolution.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-8 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling fusion-equal-height-columns\">\n<div class=\"fusion-builder-row fusion-row\">\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-14 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-column-content-centered\">\n<div class=\"fusion-column-content\">\n<div class=\"fusion-title title fusion-title-5 fusion-sep-none fusion-title-text fusion-title-size-two\">\n<h3>Comprehensive Event Mechanism<\/h3>\n<\/div>\n<div class=\"fusion-sep-clear\">&nbsp;&nbsp;<\/div>\n<div class=\"fusion-text fusion-text-10\">\n<p>The G5DFR analyzer is designed to detect any event occurring on your system. The event mechanism allows you to configure events on any measured parameter (more than 1,000) and\/or I\/O ports. The event mechanism supports out-of-limit events as well as rate of changed limits. The G5DFR records the waveform&nbsp;signals continuously. The event configuration doesn\u2019t trigger the recording but rather stores summary logs including start and end time, duration, severity and magnitude of the event. All events are&nbsp;displayed in a tabular or scatter charts as CBEME\/ITIC.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-15 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-column-content-centered\">\n<div class=\"fusion-column-content\">\n<div class=\"fusion-image-element in-legacy-container\"><span class=\"fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive wp-image-3128 lazyautosizes lazyloaded\" title=\"Power-quality-events\" src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events.png\" sizes=\"576px\" srcset=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events-200x107.png 200w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events-400x214.png 400w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events-600x321.png 600w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events.png 683w\" alt=\"\" width=\"683\" height=\"365\" data-orig-src=\"https:\/\/elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events.png\" data-srcset=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events-200x107.png 200w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events-400x214.png 400w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events-600x321.png 600w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2016\/04\/Power-quality-events.png 683w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 800px) 100vw, 600px\"><\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-9 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling fusion-equal-height-columns\">\n<div class=\"fusion-builder-row fusion-row\">\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-16 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-column-content-centered\">\n<div class=\"fusion-column-content\">\n<div class=\"fusion-image-element in-legacy-container\"><span class=\"fusion-imageframe imageframe-none imageframe-4 hover-type-none\"><img loading=\"lazy\" decoding=\"async\" class=\"img-responsive wp-image-36034 lazyautosizes lazyloaded\" title=\"IEEE 60255-118-1 certificate\" src=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2023\/05\/IEEE-60255-118-1-certificate2-1.png\" sizes=\"576px\" srcset=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2023\/05\/IEEE-60255-118-1-certificate2-1-200x150.png 200w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2023\/05\/IEEE-60255-118-1-certificate2-1-400x300.png 400w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2023\/05\/IEEE-60255-118-1-certificate2-1.png 600w\" alt=\"Phasor measurement IEEE 60255-118-1 certificate\" width=\"600\" height=\"450\" data-orig-src=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2023\/05\/IEEE-60255-118-1-certificate2-1.png\" data-srcset=\"https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2023\/05\/IEEE-60255-118-1-certificate2-1-200x150.png 200w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2023\/05\/IEEE-60255-118-1-certificate2-1-400x300.png 400w, https:\/\/www.elspec-ltd.com\/wp-content\/uploads\/2023\/05\/IEEE-60255-118-1-certificate2-1.png 600w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 800px) 100vw, 600px\"><\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-17 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-column-content-centered\">\n<div class=\"fusion-column-content\">\n<div class=\"fusion-title title fusion-title-6 fusion-sep-none fusion-title-text fusion-title-size-two\">\n<h3>Phasor Measurement Unit<\/h3>\n<\/div>\n<div class=\"fusion-sep-clear\">&nbsp; &nbsp;<\/div>\n<div class=\"fusion-text fusion-text-11\">\n<p>Complies with the most updated standard for synchrophasor measurements of power systems IEEE C37.118-2011, including the amendment IEEE C37.118.1a-2014. IEC\/IEEE 60255-118-1-2018 Certified.<\/p>\n<p>Two independent synchrophasor data streams enable to report a synchrophasor data with two different report-rates and\/or different performance classes (P\/M) and\/or data type simultaneously.<\/p>\n<p>Ultra-fast report rate for both P &amp; M classes:<\/p>\n<table border=\"1\">\n<tbody>\n<tr>\n<th>Performance Class<\/th>\n<th>Max report rate for 50Hz<\/th>\n<th>Max report rate for 60Hz<\/th>\n<\/tr>\n<tr>\n<td>P<\/td>\n<td>200\/sec<\/td>\n<td>240\/sec<\/td>\n<\/tr>\n<tr>\n<td>M<\/td>\n<td>100\/sec<\/td>\n<td>120\/sec<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Support for simultaneous synchrophasor data stream over TCP\/IP and UDP\/IP. It can be configured for unicast or multicast, enabling a better design of WAMS communication and suitable for WAMS with several utilities or applications involved.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-clearfix\">&nbsp;<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-10 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\">\n<div class=\"fusion-builder-row fusion-row\">\n<div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-18 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\">\n<div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\">\n<div class=\"fusion-title title fusion-title-7 fusion-sep-none fusion-title-text fusion-title-size-three\">\n<h3 class=\"fusion-title-heading title-heading-left\">Specifications<\/h3>\n<\/div>\n<div class=\"fusion-sep-clear\">&nbsp;<\/div>\n<div class=\"fusion-separator fusion-clearfix\">\n<div class=\"fusion-separator-border sep-single sep-solid\">&nbsp;&nbsp;<\/div><\/div>\n<div class=\"table-1\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\" align=\"left\">\n<h3>Data Acquisition<\/h3>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td align=\"left\">Sampling Rate, Maximum Samples\/Cycle<\/td>\n<td align=\"left\">256\/512\/1,024<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Digital &amp; Aux Channels Sampling Rate&nbsp;Samples\/Cycle<\/td>\n<td align=\"left\">128<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Type of Analog to Digital Converter<\/td>\n<td align=\"left\">24 Bit<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Mechanical<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Dimensions [W X H X D]<\/td>\n<td align=\"left\">21.5 x 22.1 x 29.1 cm (8.48\u201d x 8.7\u201d x 11.45\u201d)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Frequency Measurement<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Fundamental Frequency<\/td>\n<td align=\"left\">37 \u2013 70Hz<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Frequency Resolution<\/td>\n<td align=\"left\">1mHz<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Frequency accuracy<\/td>\n<td align=\"left\">\u00b11mHz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Phasor Measurement Unit \/ Synchrophasor<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Applicable Standard<\/td>\n<td align=\"left\">IEEE C37.118 \u2013 2011\/2014<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">M Class transmission Max rate<\/td>\n<td align=\"left\">100\/sec for 50Hz, 120\/sec for 60Hz<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">P Class Transmission rate<\/td>\n<td align=\"left\">200\/sec for 50Hz, 240\/sec for 60Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Communication ports (Rear Panel )<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">SFP Ports (100\/1,000MB\/s)<\/td>\n<td align=\"left\">2<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Serial Ports<\/td>\n<td align=\"left\">1<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">USB PORTS<\/td>\n<td align=\"left\">2<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">PPS<\/td>\n<td align=\"left\">1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Communication ports (Front&nbsp;Panel )<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">USB PORTS<\/td>\n<td align=\"left\">2<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Ethernet Port (10\/100MB\/s)<\/td>\n<td align=\"left\">1<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Serial<\/td>\n<td align=\"left\">1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Communication Protocols<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">IEC 61850<\/td>\n<td align=\"left\">MMS, GOOSE, Sample Value<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">MODBUS<\/td>\n<td align=\"left\">TCP\/IP, RTU<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Power Supply<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Main<\/td>\n<td align=\"left\">100 \u2013 260 VAC @50\/60 Hz or<br>100-300 VDC<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Aux<\/td>\n<td align=\"left\">24VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Time Synchronization<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Internal Real Time Clock<\/td>\n<td align=\"left\">20PPM<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">GPS<\/td>\n<td align=\"left\">0.5\u03bcsec<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">IRIG B<\/td>\n<td align=\"left\">0.5 \u03bcsec<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">NTP<\/td>\n<td align=\"left\">100 \u03bcsec<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Environmental Conditions<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Operation Temperature<\/td>\n<td align=\"left\">-20C to 70C (-40F to 1580F)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Storage Temperature<\/td>\n<td align=\"left\">\u2013 40C to 85C (-40F to 185F)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">\n<h3>Human Machine Interface<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"left\">Built in 7\u201d 1MP LCD. Additional comprehensive web server for local and remote real-time monitoring, historical data analysis and control.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Multi-Functional Digital Fault Recorder Get a Quote&gt;&gt;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;Live Demo&gt;&gt; The BlackBox G5DFR is a fully featured digital fault recorder equipped with PQZIP technology. The G5DFR\u00a0 is a distributed multi-functional data acquisition device that continuously records all waveform signals at sampling rate of 1,024 samples per cycle. PQZIP inside \u00a0Continuous waveform recordingTrigger free setup5,000 power parameters&#8230;<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2807","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/pages\/2807","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/comments?post=2807"}],"version-history":[{"count":5,"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/pages\/2807\/revisions"}],"predecessor-version":[{"id":2903,"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/pages\/2807\/revisions\/2903"}],"wp:attachment":[{"href":"https:\/\/pqs.com.pa\/en\/wp-json\/wp\/v2\/media?parent=2807"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}