Elspec is a leading global provider of advanced power quality analyzers, power quality solutions and power monitoring software. We focus on developing technology that shifts the power quality market to the next level. With over 45 years of experience, we develop tailor-made power quality solutions along with state of the art power quality analyzers.
The Compact Activar/Equalizer are static/dynamic VAR compensation systems for transient-free power factor correction and dynamic load compensation. Traditional systems are often larger, complex and expensive. Our compact systems emerge in response to these challenges for industrial and commercial sectors with limited space. With only 120(H) x 102(W) x 76(D) cm, our system’s footprint is the most efficient design offered by Elspec.
By compensating voltage drops, harmonics, voltage flickering & fluctuations, our systems enhance machinery lifetime and improve production efficiency. our compact cost-effective design offers easy upgradability, and modularity. The unique modular design enables system extensions including hybrid layout for integrated active harmonic filtration.
Key Features
• Real-time power factor correction
• High resolution compensation
• Compact & efficient design
• Alternative to conventional, larger compensation systems
• Designed for industrial & commercial applications
Compact Activar/Equalizer | |
Manufacturer | ELSPEC |
System Power | 25kVAr(400V/50Hz) to 380kVAr(480V/60Hz) |
System Size | 120(H) x102(W) x76(D) cm |
Operational Frequency | 45-55Hz for 50Hz Network 55-65Hz for 60Hz Network |
Switching | Transient free operation: Electronic switching designed to switch capacitor groups into the network without switching transients. Connection to the network during current zero-crossings, providing smooth connection and disconnection of the groups. |
Group configurations | Number of groups: Up to 3 groups per controller. Switching Sequence: · 1:1:1 · 1:2:2 · 1:2:4 |
Acquisition time EQUALIZER | Full compensation within one network cycle: · 5-20ms for 50Hz network · 4-16ms for 60Hz network |
Acquisition time ACTIVAR | One second per step. |
Control Mode | Main CT Location options: · Load only (open loop) · Load + Capacitors (close loop) Network configuration: · Single phase · Three phases WYE/DELTA balanced · Three phases WYE/DELTA unbalanced Capacitor configuration options: Single Phase – Line to Line |
Capacitors | High power capacitors: · 450V: 7.5um film thickness · 550V: 10um film thickness · 690V: 12um film thickness Maximum ratings: · Overcurrent: 4 In · Inrush current: 200 In |
Inductors | High performance cooper inductors: · Rated inductance and tolerance: -1.5% / +2.5% · Insulation voltage: 6,000V |
Losses | 208V – 480V: < 0.8% |
Operational temperature | -10°C to +40°C |
Protection class | NEMA 1 |
Communication | · Isolated RS485 · Up to 115k Baud Rate · Protocols options: Ethernet protocol ELCOM-(Elspec High-Speed communication protocol) ModBus/RTU (IEEE 754 Floating Point) · Full remote control via PQSCADA |
Operational Mode | · Manual · Automatic · Test |
Built in Power Quality measurement system | Simultaneous measurement of the following sections: · Mains (total of load and capacitor) · Load · Capacitors (system) · Combination of Mains, Load and Capacitors. |
Display | Structure: · Graphic, high contrast FSTN LCD · 4.7″, Black/White · Long life LED backlight · Antiglare coated polycarbonate window |
Controller Specifications | Power supply: 230V, 50Hz LCD Display: · Size: 94x76mm · Resolution: Graphic 160×128 pixels · Type: FSTN, LED backlight Frequency: 30 to 70 Hz Power consumption: 10VA Dimensions: 144x144x138mm, Weight: 1.4 kg Standards Electromagnetic compatibility: EN50081-2, EN50082-2, EN55011, EN61000-4-2/3/4/5, ENV50204, ENV50141. Safety standards: EN61010-1, EN50439-1 |
Switching Module | Electronic switches: · Rated voltage: 2400V/Peak · Rated Current: 350Amp Cooling: · Temperature controlled, forced air cooling system. Panel mounted · Easy Maintenance · External air circulation · Long life, Ball bearings fan Low losses: 400V: 0.35% (3.5W/kVAr) 480V: 0.30% (2.0W/kVAr) |
PC Software | PQSCADA Sapphire Software (Refer Appendix B-3): · Complete System Remote Control · Real Time measurements · Time-Of-Use and Cost Allocation · Harmonic & Waveform graphic and tabular display · Comprehensive Data Logging, including triggers and set points · Automatic comparing to international Power Quality standards, such as IEEE 519 (Harmonics standard): · Easy Report Generation · Exporting to word processor (such as Microsoft Word) and spreadsheets (such as Microsoft Excel) · User Friendly on-line help, toolbars and hints · Internet and Intranet operation · Stand-alone or network versions, allowing intra-net and internet connectivity |