Compact Activar/Equalizer

Reactive Power

compact_system3
process_2_2

Compact Reactive Power Compensation Unit

compact2

The Compact Activar/Equalizer are static/dynamic VAR compensation systems for transient-free power factor correction and dynamic load compensation. Traditional systems are often larger, complex and expensive. Our compact systems emerge in response to these challenges for industrial and commercial sectors with limited space. With only 120(H) x 102(W) x 76(D) cm, our system’s footprint is the most efficient design offered by Elspec.
By compensating voltage drops, harmonics, voltage flickering & fluctuations, our systems enhance machinery lifetime and improve production efficiency. our compact cost-effective design offers easy upgradability, and modularity. The unique modular design enables system extensions including hybrid layout for integrated active harmonic filtration.

Key Features
• Real-time power factor correction
• High resolution compensation
• Compact & efficient design
• Alternative to conventional, larger compensation systems
• Designed for industrial & commercial applications

Compact Activar/Equalizer
ManufacturerELSPEC
System Power25kVAr(400V/50Hz) to 380kVAr(480V/60Hz)
System Size120(H) x102(W) x76(D) cm
Operational Frequency45-55Hz for 50Hz Network
55-65Hz for 60Hz Network
SwitchingTransient free operation:
Electronic switching designed to switch capacitor groups into the network without switching transients.
Connection to the network during current zero-crossings, providing smooth connection and disconnection of the groups.
Group configurationsNumber of groups:
Up to 3 groups per controller. Switching Sequence:
·         1:1:1
·         1:2:2
·         1:2:4
Acquisition time EQUALIZERFull compensation within one network cycle:
· 5-20ms for 50Hz network
· 4-16ms for 60Hz network
Acquisition time ACTIVAROne second per step.
Control ModeMain CT Location options:
·         Load only (open loop)
·         Load + Capacitors (close loop)
Network configuration:
·         Single phase
·         Three phases WYE/DELTA balanced
·         Three phases WYE/DELTA unbalanced
Capacitor configuration options:
Single Phase – Line to Line
CapacitorsHigh power capacitors:
· 450V: 7.5um film thickness
· 550V: 10um film thickness
· 690V: 12um film thickness
Maximum ratings:
· Overcurrent: 4 In
· Inrush current: 200 In
InductorsHigh performance cooper inductors:
· Rated inductance and tolerance: -1.5% / +2.5%
· Insulation voltage: 6,000V
Losses208V – 480V: < 0.8%
Operational temperature-10°C to +40°C
Protection classNEMA 1
Communication·         Isolated RS485
·         Up to 115k Baud Rate
·         Protocols options:
Ethernet protocol
ELCOM-(Elspec High-Speed communication protocol)
ModBus/RTU (IEEE 754 Floating Point)
·         Full remote control via PQSCADA
Operational Mode·         Manual
·         Automatic
·         Test
Built in Power Quality measurement systemSimultaneous measurement of the following sections:
·         Mains (total of load and capacitor)
·         Load
·         Capacitors (system)
·         Combination of Mains, Load and Capacitors.
DisplayStructure:
·         Graphic, high contrast FSTN LCD
·         4.7″, Black/White
·         Long life LED backlight
·         Antiglare coated polycarbonate window
Controller SpecificationsPower supply:
230V, 50Hz
LCD Display:
·         Size: 94x76mm
·         Resolution: Graphic 160×128 pixels
·         Type: FSTN, LED backlight
Frequency:
30 to 70 Hz
Power consumption:
10VA
Dimensions:
144x144x138mm, Weight: 1.4 kg
Standards
Electromagnetic compatibility: EN50081-2, EN50082-2, EN55011, EN61000-4-2/3/4/5, ENV50204, ENV50141.
Safety standards: EN61010-1, EN50439-1
Switching ModuleElectronic switches:
·         Rated voltage: 2400V/Peak
·         Rated Current: 350Amp Cooling:
·         Temperature controlled, forced air cooling system. Panel mounted
·         Easy Maintenance
·         External air circulation
·         Long life, Ball bearings fan
Low losses:
400V: 0.35% (3.5W/kVAr)
480V: 0.30% (2.0W/kVAr)
PC SoftwarePQSCADA Sapphire Software (Refer Appendix B-3):
· Complete System Remote Control
· Real Time measurements
· Time-Of-Use and Cost Allocation
· Harmonic & Waveform graphic and tabular display
· Comprehensive Data Logging, including triggers and set points
· Automatic comparing to international Power Quality standards, such as IEEE 519 (Harmonics standard):
· Easy Report Generation
· Exporting to word processor (such as Microsoft Word) and spreadsheets (such as Microsoft Excel)
· User Friendly on-line help, toolbars and hints
· Internet and Intranet operation
· Stand-alone or network versions, allowing intra-net and internet connectivity